Tutorial 2: Aspen Plus Configuration ==================================== The files (both the Aspen Plus file and the JSON file) for this tutorial are located in: :path:`examples/tutorial_files/SimSinter/Tutorial_2` .. note:: |examples_reminder_text| #. The initial steps for opening a simulation and entering metadata for an Aspen Plus simulation are similar to ACM. Refer to the SimSinter ACM tutorial :ref:`sec.tut.simsinter.acm`. In this tutorial, a flash model “Flash_Example.bkp” (located in the above-mentioned folder) is used as an example. Open the Aspen Plus file and enter the metadata as shown in Figure :ref:`fig.sinter.ap.metadata`. .. figure:: ../figs/ap/04_MetaDataFilled_upd.png :alt: SinterConfigGUI Simulation Meta-Data with Data Completed :name: fig.sinter.ap.metadata SinterConfigGUI Simulation Meta-Data with Data Completed #. The **SinterConfigGUI Variable Configuration Page** displays as illustrated in Figure :ref:`fig.sinter.ap.variableempty`. Aspen Plus has no settings, so there are no setting variables in the input section. Unlike ACM, AspenPlus displays the **Variable Tree** on the left side, so the user can explore the tree as is done in Aspen Plus Tools :math:`\rightarrow` Variable Explorer. Unfortunately, searching is not possible. .. figure:: ../figs/ap/05_VariablesEmpty.png :alt: SinterConfigGUI Variable Configuration Page Empty Variables :name: fig.sinter.ap.variableempty SinterConfigGUI Variable Configuration Page Empty Variables #. **Variable Tree** nodes can be expanded for searching (Figure :ref:`fig.sinter.ap.expandtree`). .. figure:: ../figs/ap/06_VariablesExpanded.png :name: fig.sinter.ap.expandtree SinterConfigGUI Variable Configuration Page Expanded Aspen Plus Variable Tree #. The user can type the node address directly into the **Selected Path** field (this is useful for copy/paste from Aspen Plus’ Variable Explorer) (Figure :ref:`fig.sinter.ap.selectvar`). Click **Lookup** or **Preview** (which automatically causes the tree to expand and selects selected variables in the **Variable Tree**). .. figure:: ../figs/ap/07_VariablesSelected.png :name: fig.sinter.ap.selectvar SinterConfigGUI Variable Configuration Page Aspen Plus Variable Selected #. To make the temperature of the Flash chamber an **Input Variable**, click **Make Input**. Additionally, the user can **Name** the variable, fix the **Description**, and enter the **Min/Max** fields by clicking on the appropriate text and entering it. .. figure:: ../figs/ap/08_VariablesInput.png :alt: SinterConfigGUI Variable Configuration Page Input Variable :name: fig.sinter.ap.inputvar SinterConfigGUI Variable Configuration Page Input Variable #. Select an **Output Variable**, **Preview** it, and click **Make Output**. Next, update the fields as with the **Input Variable** to give a better **Name** and **Description**. .. figure:: ../figs/ap/09_VariablesOutput.png :alt: SinterConfigGUI Variable Configuration Page Output Variable :name: fig.sinter.ap.outputvar SinterConfigGUI Variable Configuration Page Output Variable #. The task is complete. Save it by clicking **Save** or CTRL+S. The file is saved to the location specified in the SinterConfigGUI Simulation Meta-Data page. If the user wishes to save a copy under a different name, navigate back to the SinterConfigGUI Simulation Meta-Data page and change the name.